返回: 光纖直放站(Fiber Repeater)

FIBER LINK 104/404

PDF列印
Dual-Band (1800+2100) Fiber Optic Repeater(43dBm)
無圖像集
on-order.gif
無圖像集
MU Brochure
RU Brochure
描述

Item

Specifications

Working Frequency

Uplink(MHz)

1710~1775/1920~1980

Downlink(MHz)

1805~1870/2110~2170

Working Bandwidth

65MHz/60MHz

Frequency Stability(+/-0.01ppm)

0.01ppm

RMS Output Power @ Bandwidth

43dBm

IM3@LTE1800

60dBc

Gain Flatness

±3dB for all band

AGC/ALC Function

Support

AGC/ALC Range

10dB

ACLR

3GPP TS 25.104(R10),3GPP TS 36 104(R10)

Noise Figure @ Max.Gain(DL/UL)

5dB

Spurious and Emissions

3GPP TS 25.143(R10),3GPP TS 36 143(R10)

Intermodulation

3GPP TS 25.143(R10),3GPP TS 36 143(R10)

Out of Band Gain

3GPP TS 25.143(R10),3GPP TS 36 143(R10)

EVM

3GPP TS 25.143(R10),3GPP TS 36 143(R10)

Group(System) Delay

1.5us

Ingress Protection

IP65

Cooling Function

Heat sink

Local Monitoring Interface

USB2.0/RJ45

Remote Monitoring Module

Through MU via fiber

Optical Connector Type

1xLC/UPC

RF Connector Type

1xN-Female or 1xDIN-Female

Operating Temperature

-10℃~55℃

Relative Humidity

85%

Dimensions

780mm×420mm×230mm

Mounting Type

Wall & Pole

Power Supply

AC100V~AC240V, 50/60Hz

Power Supply Protection

Include short circuit, Over Voltage and Surge protection

Power Consumption

250W

Battery Backup/Time

30minutes

MTBF

>50000hours

Software Support MU/RU Models

Same EMS support different model of MU/RU

Adjustable Parameters Function

Set and display MU and RU ID and Location, adjust the Downlink/Uplink gain,
turn on/off the RF power amplifier, remote turn on/off or restart RU;

Monitored Parameters

Real-time status for downlink/Uplink output power(RSSI),temperature, optical power;

Alarm Type Classification

Three levels (such as Major, Minor, and Warning)

Alarm Parameters

Real-time alarm for door status, temperature, power supply, VSWR, etc;

Interface Remote/Local Software

Terminal software suitable for Windows 7 and the above system

EMS Server

Provide GUI interface for configuration the MU and RU, remote management
each RU by MU, to set the parameters of RU, and monitoring the status and alarms